ULP Law Pressure RO Element
ULP Law Pressure RO Element

ULP Law Pressure RO Element

MOQ : 1 Unit

ULP Law Pressure RO Element Specification

  • Accessories
  • O-Rings, Membrane Seal
  • Flow Rate
  • Maximum continuous permeate flow as specified
  • Technology
  • RO Membrane Technology
  • Features
  • High salt rejection, low-pressure operation, energy saving, suitable for low TDS brackish water
  • Usage
  • RO Water Treatment Systems
  • Type
  • ULP (Ultra Low Pressure) Law Pressure RO Element
  • Material
  • Polyamide (PA) Composite
  • Purifying Function
  • Reverse Osmosis (RO)
  • Installation Type
  • Membrane Housing Mount
  • Temperature
  • 5C - 45C
  • Water Source
  • Brackish Water / Tap Water
  • Dimension (L*W*H)
  • 40 inch (Length) x 4 inch (Diameter)
  • Weight (kg)
  • ~3.8 kg
  • Application
  • Industrial and Commercial Water Purification
  • Capacity
  • 2200 GPD (Gallons per Day)
  • Mounting Type
  • Horizontal Mount
  • Industry Standards
  • Complies with international RO membrane standards
  • Membrane Type
  • Thin Film Composite (TFC)
  • Element Configuration
  • Spiral Wound
  • End Cap Type
  • Double Open Ended (DOE)
  • Free Chlorine Tolerance
  • < 0.1 ppm
  • Recovery Rate
  • Up to 75% (subject to system design)
  • Salt Rejection Rate
  • 97% (Nominal)
  • Maximum Feed Flow Rate
  • 16 GPM (Gallons per Minute)
  • pH Range (Operation)
  • 2 - 11
  • Maximum Operating Pressure
  • 150 psi (10.3 bar)
  • Recommended Cleaning pH
  • 1 - 13
 

ULP Law Pressure RO Element Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 1000 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About ULP Law Pressure RO Element



Introducing the new release ULP Law Pressure RO Element-a best-seller in advanced industrial and commercial water purification. Crafted with distinguished Thin Film Composite (TFC) technology and a pristine polyamide build, it boasts a virtuoso salt rejection rate of 97% (nominal) and up to 75% recovery. Engineered for energy-efficient, low-pressure operation (max 150 psi), this top-rated RO membrane delivers up to 2200 GPD. Complying with international standards, it excels with brackish or tap water, ensuring sustainable, superior-quality water treatment for any demanding application.

Versatile Applications and Competitive Advantages

The ULP Law Pressure RO Element is ideal for both industrial and commercial water purification, efficiently treating brackish or tap water. Its competitive advantages include high salt rejection, low-pressure operation, and significant energy savings. Widely used by water treatment professionals, manufacturers, and businesses seeking reliable, cost-effective solutions, this element provides unmatched performance for RO systems across various sectors, distinguishing itself as a leader in the market.


Sample Policy, Main Domestic Market, and FOB Port Information

We offer a transparent sample policy, with shipment of ULP Law Pressure RO Element samples available at the lowest price for qualified buyers. Serving the main domestic market across India, our products meet stringent standards and industry requirements. Shipments are dispatched from our designated FOB port, ensuring prompt delivery and hassle-free transactions. We maintain a strong commitment to quality, customer satisfaction, and reliable domestic market supply.


FAQ's of ULP Law Pressure RO Element:


Q: How does the ULP Law Pressure RO Element enhance water purification efficiency?

A: The ULP Law Pressure RO Element utilizes advanced Thin Film Composite technology, enabling high salt rejection at ultra-low pressure. This design results in efficient, energy-saving water purification suitable for industrial and commercial applications.

Q: What types of water sources are compatible with this RO element?

A: It is designed for use with brackish water and tap water, making it ideal for a variety of water treatment systems where lower total dissolved solids (TDS) are present.

Q: When should the membrane be cleaned and what pH range is recommended for cleaning?

A: Periodic cleaning is recommended to maintain performance. The membrane can be cleaned within a pH range of 1 to 13 for effective removal of fouling or scaling substances.

Q: Where is the ULP Law Pressure RO Element typically installed?

A: It is installed in membrane housing mounts within industrial and commercial RO water treatment systems, with a preferred horizontal mounting configuration for optimal operation.

Q: What are the primary benefits of using this RO element in a water treatment system?

A: Key benefits include a high salt rejection rate (97%), low-pressure operation, up to 75% recovery, energy savings, and compliance with international industry standards, making it a top choice for efficient water purification.

Q: How does the product ensure durability and long-term performance?

A: The element is crafted from pristine polyamide composite materials and features a robust spiral-wound configuration, ensuring distinguished durability and consistent high performance even under challenging conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Meetec Membrane Elements Category

Law Pressure RO Element

Law Pressure RO Element

Minimum Order Quantity : 1 Unit

Application : Industrial RO Plant, Commercial RO Systems

Capacity : 2500 GPD (Gallons Per Day)

Installation Type : Other, Standard RO Housing Mount

Temperature : 4C 45C

Flow Rate : 9.5 m3/day (approx. 2500 GPD)

Residential Membrane Element

Residential Membrane Element

Minimum Order Quantity : 1 Unit

Application : Domestic and residential water purification

Capacity : 75 GPD (Gallons Per Day)

Installation Type : Other, Inline/Inside RO system housing

Temperature : 5C 45C

Flow Rate : 1215 LPH (Liters Per Hour)

Residential Membrane Elements

Residential Membrane Elements

Minimum Order Quantity : 1 Unit

Application : Residential RO Water Purifiers

Capacity : 80100 GPD (Gallons per Day)

Installation Type : Other, Fits inside standard RO housings

Temperature : 5C to 45C

Flow Rate : ~1215 liters/hour (Depending on water pressure)

MEETEC Plus RO Element

MEETEC Plus RO Element

Minimum Order Quantity : 1 Unit

Application : Commercial/Industrial Water Purification

Capacity : 2500 GPD

Installation Type : Other, Industrial

Temperature : 5 to 45C

Flow Rate : 2500 Gallons/Day



We deal only in bulk orders.
Back to top